Flood sensor iO (10002860-039) manual for Z-Wave

The following is an overview of the user manual for the Z-Wave product Flood sensor iO (10002860-039)from Simon. To view other Z-Wave products and manuals from Simon follow that link.

  1. Overview
  2. Security
  3. Features
  4. Installation instructions

Overview

Name
Flood sensor iO
SKU Code
10002860-039
Description
Flood Sensor is capable of both detecting leaks and floods and when the level of water gets too low in pool or tank, Flood Sensor can work with your Z-Wave network to prevent emergencies such as burst water boiler to leaking air conditioners. With Z-Wave, the scope to save money is endless.

The features list:
1) Z-Wave Plus certified for wide compatibility (500 serials product).
2) Security 0 and Security 2 framework implemented with AES-128 encryption.
3) Contains an extension water detecting probe.
4) Temperature measurement.
5) Vibration sensor.
6) The battery life is up to 1 year.
7) Low battery alert
Version #
HW: 1 FW: 1.01 was the version certified
Certification #
ZC10-20076939
Certified
2020-07-08T16:11:32.463706
Z-Wave Version
6.71.01

Security

As a Z-Wave Plus certified product, Flood sensor iO supports Z-Wave S2 security. The following security modes are directly supported:

  • S2 Unauthenticated

Features

Simon describes Flood sensor iO as having the following features:

  • Supported Notification Types
  • Sensors
  • Battery Quantity
  • Firmware updatable via a compatible Z-Wave gateway
  • Battery powered using batteries
  • Color
  • FLiRS capable
  • Supports Network Wide Inclusion
  • Supports Z-Wave Explorer Frames
  • Supports Z-Wave SmartStart allowing you to setup the product simply by scanning its QR code via

Installation instructions

Triple click the Z-button quickly,and then the dut will enter into the Learn Mode.

Press and hold the Z button for more than 5 seconds and release.

None

1) Open the cover.
2) Place the device within the direct range of your Z-Wave controller.
3) Set the main controller remove mode (see the controller’s manual).
4) Triple click the Z-button quickly, the LED indicator should blink fast.
5) Wait for the removing process to end.
6) Successful adding will be confirmed by the Z-Wave controller’s message.

Factory reset Flood sensor iO

1)Power on the device,
2) Press and hold the Z button for more than 20 seconds,
3) If holding time more than 20seconds, the LED indicator will keep on for 2 seconds, which means resetting is complete.
4) The reset feature works only when the device has been included into a Z-Wave network.

Use this procedure only in the event that the network primary controller is missing or otherwise inoperable.
Please use this procedure only when the network primary controller is missing or otherwise inoperable.

1) Open the cover.
2) Place the device within the direct range of your Z-Wave controller.
3) Set the main controller in add mode (see the controller’s manual).
4) Click the Z-button once or triple click the Z-button quickly, the LED indicator should blink fast.
5) Wait for the adding process to end.
6) Successful adding will be confirmed by the Z-Wave controller’s message.

Please note that this is a user manual Flood sensor iO from Simon is provided as is and without warranty; all information contained herein is provided by the manufacturer or the certifying body. The information provided is for reference only and is not intended to be used as a substitute for professional advice. ZWaveProducts.com only warrants and is only able to support products purchased directly from us. If you have Flood sensor iO and have not purchased it from us, please contact the manufacturer directly with any further questions you may have.