Overview

Name
carbon monoxide alarm
SKU Code
GS816B
Description
GS816B is wireless carbon monoxide (CO) alarm,This device is a product that has been built using state-of-the-art technology. This detector is a Z-Wave enabled device and is fully compatible with any Z-Wave enabled network and it’s security framework.
Version #
HW: 255 FW: 1.01:01.01 was the version certified
Certification #
ZC10-17095775
Certified
2017-09-14T16:54:51.17521
Z-Wave Version
6.71.01

Security

As a Z-Wave Plus certified product, carbon monoxide alarm supports Z-Wave S2 security. The following security modes are directly supported:

  • S2 Unauthenticated

Features

siterwell describes carbon monoxide alarm as having the following features:

  • Battery Quantity
  • Battery powered using AA batteries
  • Supported Notification Types
  • FLiRS capable
  • Supports Network Wide Inclusion
  • Supports Z-Wave Explorer Frames
  • Supports Z-Wave SmartStart allowing you to setup the product simply by scanning its QR code via

Installation instructions

For “Exclusion” from (removing from) a network:
a: Put the Z-Wave Interface Controller into “exclusion” mode.
b: Power on the detector, in 2 seconds, press the button three times in the warm-up state or the normal standby state, this detector will be automatically remove from the controller network with the red light flash every two seconds. If the network is exclusion successful, the red led
4 / 8
always on about 5 seconds, else the yellow led always on 5 seconds.
Note: Exclusion network status, you can click on the button to exit.
Note: If the alarm is remove(excluded), then the sensor will be itself restored to factory default settings.

For “Inclusion” in (adding to) a network:
a: Put the Z-Wave interface controller into “include” mode, and following its instruction to add the GS816B to your controller. To get in the “inclusion” mode, the position of the detector and controller should be kept in the usual working position.
b: Power on the detector, in 2 seconds, press the button three times in the warm-up state or the normal standby state, this detector will be automatically with the controller network with the red light flash every two seconds. If the network is successful, the red led always on about 5 seconds, else the yellow led always on 5 seconds.
Note: Inclusion network status, you can click on the button to exit.

Factory reset carbon monoxide alarm

It happens automatically when the device is excluded or you can use the following steps to reset factory settings.
a: Remove the battery.
b: Press the button and don't let go. And then connecting the battery, the red led will on 3 seconds,3 seconds later, when the red light is off, then release the button.
c. When the button is released, the red light is lit for 3 seconds. In these 3 seconds, press the button, then the red led will flash quickly about 10 seconds (NOTE: Do not turn off the power when the red led flashes). After successful recovery factory settings, the product into preheating state.
Note: If this sensor is reset, the information of Z-Wave network in the sensor will be deleted. The sensor will be itself restored to factory default settings. Please use this procedure only when the network primary controller is missing or otherwise inoperable.
NOTE: Damage to the ZWAVE module will not affect the main function of the alarm, only affect the module related functions.

Please note that this is a user manual carbon monoxide alarm from siterwell is provided as is and without warranty; all information contained herein is provided by the manufacturer or the certifying body. The information provided is for reference only and is not intended to be used as a substitute for professional advice. ZWaveProducts.com only warrants and is only able to support products purchased directly from us. If you have carbon monoxide alarm and have not purchased it from us, please contact the manufacturer directly with any further questions you may have.