Blind-curtain motor controller (SY-IOT101) manual for Z-Wave

The following is an overview of the user manual for the Z-Wave product Blind-curtain motor controller (SY-IOT101)from Somfy. To view other Z-Wave products and manuals from Somfy follow that link.

  1. Overview
  2. Security
  3. Features
  4. Installation instructions

Overview

Name
Blind-curtain motor controller
SKU Code
SY-IOT101
Description
Z-Wave™ enabled devices displaying the Z-Wave™ logo can also be used with it regardless of the manufacturer, and ours can also be used in other manufacturer’s Z-Wave™ enabled networks. Users easily control the curtain to open and close by sending Z-Wave™ signal from Z-Wave™ Interface Controller. This module will send open/close signal to the appliance that attached to this module by receiving Z-Wave™ signal from controller or manually switch. Our special design the curtain not only can be opened and closed but also can be stopped under the Multilevel Switch command on the controller. When the device is secure included into Z-Wave network, above communication will be encrypted. This module also acts as repeater
Version #
HW: 1 FW: 39.16 was the version certified
Certification #
ZC10-17075691
Certified
2017-07-13T22:29:06.243738
Z-Wave Version
6.61.00

Security

As a Z-Wave Plus certified product, Blind-curtain motor controller supports Z-Wave S2 security. The following security modes are directly supported:

    Features

    Somfy describes Blind-curtain motor controller as having the following features:

    • Color
    • Communications Protocol
    • Communications Connections
    • Firmware updatable via a compatible Z-Wave gateway
    • Window Covering Control Features
    • FLiRS capable
    • Supports Network Wide Inclusion
    • Supports Z-Wave Explorer Frames
    • Supports Z-Wave SmartStart allowing you to setup the product simply by scanning its QR code via

    Installation instructions

    Factory reset Blind-curtain motor controller

    Local Reset (Factory Default Reset )
    - Press the program switch for above 10 second, then the LED is blinked until program switch is released.
    - Release from the program switch.
    - Then, SY-IOT101 module will try local reset.
    - If local reset is succeeded, LED is blinked 5 times.
    - After blinking LED, SY-IOT101 will send the “Device Reset Locally Notification” command and reset to the factory default.
    - If local reset is failed, LED is turn off.
    * Please use this procedure only when the network primary controller is missing or otherwise inoperable.

    For “Manual Control Mode”
    Press and hold Up Switch : UP
    Press and hold Down Switch: Down
    Release Up & Down Switch: Stop

    For “Exclusion” removing from the network: Put the Z-Wave™ Interface Controller into “exclusion” mode, and following its instruction to add the SY-IOT101 to your controller. To get in the “exclusion” mode.
    - Check if SY-IOT101 module is in inclusion mode
    - Press the program switch for above 5 second, then the LED is turned on.
    - Release from the program switch.
    - Then, SY-IOT101 module will try inclusion.
    - If inclusion is succeeded, LED is blinked 3 times.
    - If exclusion is failed, LED is turn off.

    For “Inclusion” in (adding to) a network: Put the Z-Wave™ Interface Controller into “inclusion” mode, and following its instruction to add the SY-IOT101to your controller. To get in the “inclusion” mode.
    - Check if SY-IOT101 module is in exclusion mode.
    - Press the program switch for above 5 second, then, the LED is turned on.
    - Release from the program switch.
    - Then, SY-IOT101 module will try inclusion.
    - If inclusion is succeeded, LED is blinked 3 times.
    - If inclusion is failed, LED is turn off.

    Device Learn Mode : This mode is for factory default or service mode (curtain or blind mode), not used by user.
    * Entering this learn mode is some difficult, because this mode is only for factory or service mode.
    - Put curtain or blind at close position first with remote or electrical switch.
    - Press the program switch for 300(ms) and release it after 900(ms) as following.
    . When press & release the program switch at first time, LED will be blink one time.
    . When press & release the program switch at second time, LED will be blink two times.
    . When press & release the program switch at third time, LED will be blink three times

    - After LED blink three times, module will try device learn.
    - Open the curtain or blind. Then, close the curtain or blind.
    - This mode is to distinguish the device (curtain or blind) and measure the total distance between up and down in case of blind device.

    Please note that this is a user manual Blind-curtain motor controller from Somfy is provided as is and without warranty; all information contained herein is provided by the manufacturer or the certifying body. The information provided is for reference only and is not intended to be used as a substitute for professional advice. ZWaveProducts.com only warrants and is only able to support products purchased directly from us. If you have Blind-curtain motor controller and have not purchased it from us, please contact the manufacturer directly with any further questions you may have.