The following is an overview of the user manual for the Z-Wave product In Wall Dual Relay (1 Way) Switch Module (TZ04)from TKB Home. To view other Z-Wave products and manuals from TKB Home follow that link.
Overview
This in-wall switch module is able to detect Instant power wattage and overload current (7.5A with resistive load) of connected light or appliances. When detecting overload state, the Module will be disabled and its On/Off button will be lockout of which LED will flash quickly. However, disconnect and re-connect the Module will reset its overload condition to normal status.
Adding to Z-WaveTM Network
In the front casing, there is an on/off button with LED indicator below which is used to toggle switch on and off or carry out inclusion, exclusion, reset or association. When first power is applied, its LED flashes on and off alternately and repeatedly at 0.5 second intervals. It implies that it has not been assigned a node ID and start auto inclusion.
Auto Inclusion
The function of auto inclusion will be executed as long as the in wall switch does not have Node ID and just connect the switch to main power.
Note: Auto inclusion timeout is 2 minute during which the node information of explorer frame will be emitted once every several seconds. Unlike “inclusion” function as shown in the table below, the execution of auto inclusion is free from pressing the On/Off button on the Switch.
Security
As a Z-Wave Plus certified product, In Wall Dual Relay (1 Way) Switch Module supports Z-Wave S2 security. The following security modes are directly supported:
Features
TKB Home describes In Wall Dual Relay (1 Way) Switch Module as having the following features:
- FLiRS capable
- Supports Network Wide Inclusion
- Supports Z-Wave Explorer Frames
- Supports Z-Wave SmartStart allowing you to setup the product simply by scanning its QR code via
Installation instructions
1. Put your Z-Wave controller into exclusion mode by following the instructions provided by the controller manufacturer.
2. Pressing INCLUDE_BUTTON three times within 2 seconds will enter exclusion mode.
3. Node ID has been excluded.
1. Put your Z-Wave controller into inclusion mode by following the instructions provided by the controller manufacturer.
2. Pressing INCLUDE_BUTTON three times within 2 seconds will enter inclusion mode.
Factory reset In Wall Dual Relay (1 Way) Switch Module
Use this procedure only in the event that the primary controller is lost or otherwise inoperable.
1. Pressing INCLUDE_BUTTON three times within 2 seconds will enter inclusion mode.
2. Within 1 second, press On/Off button again for 5 seconds.
3. IDs are excluded.
Please note that this is a user manual In Wall Dual Relay (1 Way) Switch Module from TKB Home is provided as is and without warranty; all information contained herein is provided by the manufacturer or the certifying body. The information provided is for reference only and is not intended to be used as a substitute for professional advice. ZWaveProducts.com only warrants and is only able to support products purchased directly from us. If you have In Wall Dual Relay (1 Way) Switch Module and have not purchased it from us, please contact the manufacturer directly with any further questions you may have.