Window Sensor (FGDW-002) manual for Z-Wave

The following is an overview of the user manual for the Z-Wave product Window Sensor (FGDW-002)from Venture WISE. To view other Z-Wave products and manuals from Venture WISE follow that link.

  1. Overview
  2. Security
  3. Features
  4. Installation instructions

Overview

Name
Venture WISE Window Sensor
SKU Code
FGDW-002
Description
Venture WISE Window Sensor is a wireless, battery powered Hall effect contact sensor,
compatible with the Z-Wave Plus™ standard. Changing the device’s
status will automatically send signal to the Z-Wave™ controller and
associated devices.
Sensor can be used to trigger scenes and wherever there is a need
for information about opening or closing of doors, windows, garage
doors, etc. Opening is detected by separating the sensor’s body and
the magnet.
In addition the Sensor is equipped with a built-in temperature
sensor.

Main features of Sensor:
- Compatible with any Z-Wave™ or Z-Wave Plus™ Controller,
- Supports protected mode (Z-Wave™ network Security Mode) with
AES-128 encryption,
- Door/window opening detected through separation of Sensor’s
body and a magnet,
- Built-in temperature sensor,
- Detects tampering, when detached or opened,
- Easily mounted on doors, windows, garage gates and roller blinds,
- Battery powered,
- Visual LED indicator signaling status of the device,
- 7 color variations.
Version #
HW: 2 FW: 3.02 was the version certified
Certification #
ZC10-22127118
Certified
2022-12-13T12:30:12.99733
Z-Wave Version
6.51.09

Security

As a Z-Wave Plus certified product, Window Sensor supports Z-Wave S2 security. The following security modes are directly supported:

    Features

    Venture WISE describes Window Sensor as having the following features:

    • Battery Quantity
    • Battery powered using ER14250 or CR2 batteries
    • Firmware updatable via a compatible Z-Wave gateway
    • Sensors
    • Supported Notification Types
    • FLiRS capable
    • Supports Network Wide Inclusion
    • Supports Z-Wave Explorer Frames
    • Supports Z-Wave SmartStart allowing you to setup the product simply by scanning its QR code via

    Installation instructions

    Factory reset Window Sensor

    Resetting the Sensor:
    Reset procedure allows to restore the device back to its factory settings,
    which means all information about the Z-Wave controller and
    user configuration will be deleted.
    In order to reset the device:
    1. Open the cover.
    2. Remove the battery.
    3. Install the battery while holding both TMP buttons.
    4. Visual LED indicator will be flashing slowly for 5 seconds - keep
    holding the buttons.
    5. Release one button when the LED indicator starts flashing quickly.
    6. Click released button once to confirm launching of reset procedure.
    7. Wait a few seconds until a long blink of the LED indicator. Do not
    remove the battery.
    8. Visual LED indicator will blink 5 times quickly to confirm the reset.

    Waking up the Sensor:
    The Sensor needs to be woken up to receive information about the
    new configuration from the controller, like parameters and associations.
    To wake up the sensor manually, click one of the TMP buttons (while
    the other button is pressed).

    Removing (Exclusion) - Z-Wave device learning mode, allowing to
    remove the device from existing Z-Wave network.
    To remove the device from the Z-Wave network:
    1. Place the Sensor within the direct range of your Z-Wave controller.
    2. Set the main controller into remove mode (see the controller’s
    manual).
    3. Quickly, three times press one of the TMP buttons (while the other
    button is pressed).
    4. Wait for the removing process to end.
    5. Successful removing will be confirmed by the Z-Wave controller’s
    message.

    Adding (Inclusion) - Z-Wave device learning mode, allowing to add
    the device to existing Z-Wave network.
    To add the device to the Z-Wave network:
    1. Place the Sensor within the direct range of your Z-Wave controller.
    2. Set the main controller in (Security/non-Security Mode) add mode
    (see the controller’s manual).
    3. Quickly, three times press one of the TMP buttons (while the other
    button is pressed).
    4. Wait for the adding process to end.
    5. Successful adding will be confirmed by the Z-Wave controller’s
    message.

    Please note that this is a user manual Window Sensor from Venture WISE is provided as is and without warranty; all information contained herein is provided by the manufacturer or the certifying body. The information provided is for reference only and is not intended to be used as a substitute for professional advice. ZWaveProducts.com only warrants and is only able to support products purchased directly from us. If you have Window Sensor and have not purchased it from us, please contact the manufacturer directly with any further questions you may have.