VI EU on-off 6 triac 916.0 MHz (01EE6S263) manual for Z-Wave

The following is an overview of the user manual for the Z-Wave product VI EU on-off 6 triac 916.0 MHz (01EE6S263)from Vitrum. To view other Z-Wave products and manuals from Vitrum follow that link.

  1. Overview
  2. Security
  3. Features
  4. Installation instructions

Overview

Name
Vitrum VI EU on-off 6 triac 916.0 MHz
SKU Code
01EE6S263
Description
Vitrum can easily be installed in common flush-mounting boxes, and does not require buses, control units or additional wiring. It uses the most widespread technologies in the world, and offers an advanced and intuitive user experience and is offered in different collections to choose the style that best suits your needs. The great versatility of Vitrum simplifies home automation and makes it available to everyone.
Version #
HW: 1 FW: 5.50:01.01 was the version certified
Certification #
ZC10-20076946
Certified
2020-07-15T12:00:17.494251
Z-Wave Version
6.71.03

Security

As a Z-Wave Plus certified product, VI EU on-off 6 triac 916.0 MHz supports Z-Wave S2 security. The following security modes are directly supported:

  • S2 Unauthenticated

Features

Vitrum describes VI EU on-off 6 triac 916.0 MHz as having the following features:

  • Switch Type
  • Z-Wave Scene Type
  • Firmware updatable via a compatible Z-Wave gateway
  • Loads Controlled
  • Neutral Wire Required
  • Switch Load Capacity Current
  • Switch Load Capacity Volt-Ampere
  • Switch Load Capacity Watts
  • FLiRS capable
  • Supports Network Wide Inclusion
  • Supports Z-Wave Explorer Frames
  • Supports Z-Wave SmartStart allowing you to setup the product simply by scanning its QR code via

Installation instructions

The device supports both Normal Add and Network Wide Add.
The device supports encryption S2 Unauthenticated.
Follow the steps below to add the device to the network.

How to check the device is added to the network
Press N.1 button shortly. The LED button blinks shortly red whether the device is
removed from the network.

1. Set primary controller into Add mode (please see controller instruction
manual) and operate on it to enable S2 Unauthenticated encryption or
disable encryption
2. Check the device is not already added to the network (please refer to the
manual section “How to check the device is added to the network”)
3. Press and hold button N.1 located on top-left front-end device more then 4
seconds till button LED blinks shortly magenta or press shortly the Physical
button located on the front end top-back device
4. Every device LED button blinks green shortly 3 times upon the device added
successfully
Should the device fail the Normal Add the device enter into Wide Add mode up to
4 times. Any time the device enters into Wide Add Mode, LED Button N.1 blinks
Magenta and keeps on emits a short beep.

How to check the device is added to the network
Press N.1 button shortly. The LED button blinks shortly red whether the device is
removed from the network.

1. Set primary controller into Remove mode (please see controller instruction
manual)
2. Check the device is not already removed from the network (please refer to
the manual section “How to check the device is added to the network”)
3. Press and hold button N.1 located on top-left front-end device more then 6
seconds till the device emits a long beep. Release the button and press it
shortly 3 times again or press shortly the Physical button located on the
front end top-back device
4. Button LED blinks shortly red upon the device removed successfully.
5. Check the device is removed from the network (please refer to the manual
section “How to check the device is added to the network”)

Remove the device from a certified Z-Wave network
1. Set primary controller into Remove mode (please see controller instruction manual)
2. Check the device is not already removed from the network (please refer to the manual section “How to check the device is added to the network”)
3. Press and hold button N.1 located on top-left front-end device more then 6 seconds till the device emits a long beep. Release the button and press it shortly 3 times again or press shortly the Physical button located on the front end top-back device
4. Button LED blinks red shortly upon the device removed successfully.
5. Check the device is removed from the network (please refer to the manual section “How to check the device is added to the network”)

How to check the device is added to the network
Press button N.1 shortly. The LED button blinks red shortly whether the device is not added to the network.

Control lights directly using 'ON'/'OFF' buttons
Control of groups of other Z-Wave devices using 'ON'/'OFF' buttons
Activation of scenes in Gateways.
Touch operated button with RGB back-light
Very low standby power consumption
Triac switching at zero crossing point of AC
Easy installation
Acoustic feedback at button press.

Factory reset VI EU on-off 6 triac 916.0 MHz

Press and hold the Physical button for about 5 seconds till the buzzer plays a long beep, release the button and press it again till the buzzer plays a sequence of 3 short beeps, than release the button.
Warning: don’t care the 2 short beeps played after 2 seconds from start and keep on pressing the button till the buzzer plays the 3 short beeps sequence.
See Factory reset below for more details and notes.

Factory reset
During factory reset the device sends a Device Reset Locally notification from the Lifeline group.
The device reverts to its factory default settings, blinking all LED buttons and reboots and send the Device Reset Locally Notification from the Lifeline group.
Do not disconnect the device from power supply till rebooting is completed.
Configuration and settings are restore to default values.
Home ID and Node ID are cleared as well.

Add the device to a certified Z-Wave network
The device supports both Classic Add (Classic Inclusion) and Network Wide Add (Network Wide Inclusion).
The device supports encryption S2 Unauthenticated.
Follow the steps below to add the device to the network.
1. Set primary controller into Add mode (please see controller instruction manual) and operate on it either to enable S2 Unauthenticated encryption or to disable encryption
2. Check the device is not already added to the network (please refer to the manual section “How to check the device is added to the network”)
3. Press and hold button N.1 located on top-left front-end device more then 4 seconds till button LED blinks shortly magenta or press shortly the Physical button located on the front-end top-back device (see section “Physical Button Operating” to locate Physical Button).
4. Every device LED button blinks green shortly 3 times upon the device added successfully

Should the device fail the Classic Add (Classic Inclusion) the device enters into Network Wide Add (Network Wide Inclusion) mode up to 4 times. Any time the device enters into Wide Add Mode, LED Button N.1 blinks Magenta and keeps on to emit a short beep.

How to check the device is added to the network
Press button N.1 shortly. The LED button blinks red shortly whether the device is not added to the network.

Please note that this is a user manual VI EU on-off 6 triac 916.0 MHz from Vitrum is provided as is and without warranty; all information contained herein is provided by the manufacturer or the certifying body. The information provided is for reference only and is not intended to be used as a substitute for professional advice. ZWaveProducts.com only warrants and is only able to support products purchased directly from us. If you have VI EU on-off 6 triac 916.0 MHz and have not purchased it from us, please contact the manufacturer directly with any further questions you may have.