4 in 1 multi sensor (WK-0002) manual for Z-Wave

The following is an overview of the user manual for the Z-Wave product 4 in 1 multi sensor (WK-0002)from WINKA SYSIT. To view other Z-Wave products and manuals from Winka Sysit follow that link.

  1. Overview
  2. Security
  3. Features
  4. Installation instructions

Overview

Name
4 in 1 multi sensor
SKU Code
WK-0002
Description
4 in 1multi sensor, Function includes Motion detected, Door/window detected, Tampering detected, Ambient light intensity /temperature measured.
Version #
HW: 16 FW: 1.32:01.33 was the version certified
Certification #
ZC10-17105818
Certified
2017-10-26T22:50:41.98857
Z-Wave Version
6.51.09

Security

As a Z-Wave Plus certified product, 4 in 1 multi sensor supports Z-Wave S2 security. The following security modes are directly supported:

    Features

    Winka Sysit describes 4 in 1 multi sensor as having the following features:

    • Battery Quantity
    • Battery powered using CR123A batteries
    • Sensors
    • Supported Notification Types
    • FLiRS capable
    • Supports Network Wide Inclusion
    • Supports Z-Wave Explorer Frames
    • Supports Z-Wave SmartStart allowing you to setup the product simply by scanning its QR code via

    Installation instructions

    a) Ensure that the sensor is powered up correctly.
    b) Set Z-Wave Gateway entered inclusion mode.
    c) Press the tamper button on the back of the sensor for three times quickly within 1.5 seconds. Then the LED
    light will flash for 10 times with an interval of one second, which means that the sensor has entered the
    mode of networking and it is waiting for the gateway to complete the configuration.

    a) Ensure that the sensor is powered up correctly.
    b) Set Z-Wave Gateway entered exclusion mode.
    c) Press the tamper button on the back of the sensor for three times quickly within 1.5 seconds. Then the LED
    light will flash for 10 times with an interval of 500ms, which means that the sensor has entered the mode
    of removing from the network and it is waiting for the host to complete the configuration.

    Factory reset 4 in 1 multi sensor

    a) Ensure that the sensor is powered up correctly.
    b) Remove the sensor cover on the top, press the tamper button on the top of the sensor three times quickly within 1.5s. Then sensor will erase all data and restore to the defaults and the LED will flash for 10times with an interval of 500ms.
    Note: This mode can also erase the network information of the sensor and make the device removed from the Z-Wave network that it has included. Please use this procedure only when the network primary controller is missing or otherwise inoperable.

    First, press the both two tamper buttons on the both side of the device simultaneously and then power the
    sensor up, which will make it enter the factory testing mode. In this mode, no sensor function works, and the
    LED light will keep flashing.
    Exit from factory test mode: Power off and then power the socket on by un-pressing two buttons. And then it
    will enter the normal working mode.

    Press the tamper button on the back of the sensor shortly. Then the LED will flash once. If the sensor has added
    in a Z-Wave network, the sensor will send WAKE_UP_INFORMATION message to the gateway.
    If the tamper button is pressed for three times quickly, the sensor will broadcast NODE_INFO messages.

    Please note that this is a user manual 4 in 1 multi sensor from WINKA SYSIT is provided as is and without warranty; all information contained herein is provided by the manufacturer or the certifying body. The information provided is for reference only and is not intended to be used as a substitute for professional advice. ZWaveProducts.com only warrants and is only able to support products purchased directly from us. If you have 4 in 1 multi sensor and have not purchased it from us, please contact the manufacturer directly with any further questions you may have.