Outlet (WK-0003) manual for Z-Wave

The following is an overview of the user manual for the Z-Wave product Outlet (WK-0003)from WINKA SYSIT. To view other Z-Wave products and manuals from Winka Sysit follow that link.

  1. Overview
  2. Security
  3. Features
  4. Installation instructions

Overview

Name
Outlet
SKU Code
WK-0003
Description
This is a smart power plug, function includes Switch, Electrical parameters measure, Over-current protection & timing. Lets you wirelessly control whatever device is plugged into it remotely, from a schedule, or from the outlet iteself. This smart switch has electrical parameters measure, you can see the electricity which your device are using in real time from APP.
Version #
HW: 16 FW: 1.36 was the version certified
Certification #
ZC10-17105819
Certified
2017-10-27T00:11:10.137484
Z-Wave Version
6.51.09

Security

As a Z-Wave Plus certified product, Outlet supports Z-Wave S2 security. The following security modes are directly supported:

    Features

    Winka Sysit describes Outlet as having the following features:

    • Supported Meter Type
    • Supported Notification Types
    • Switch Type
    • FLiRS capable
    • Supports Network Wide Inclusion
    • Supports Z-Wave Explorer Frames
    • Supports Z-Wave SmartStart allowing you to setup the product simply by scanning its QR code via

    Installation instructions

    a) Ensure that the outlet is powered up correctly.
    b) Set Z-Wave Gateway entered inclusion mode.
    c) Press the button on the outlet for three times quickly within 1.5 seconds. Then the LED light will flash for
    5 times with an interval of 500ms, which means that the outlet has entered the inclusion mode and it is
    waiting for the gateway to complete the configuration.

    a) Ensure that the outlet is powered up correctly.
    b) Set Z-Wave Gateway entered exclusion mode.
    c) Press the button on the outlet for three times quickly within 1.5 seconds. Then the LED light will flash for
    5 times with an interval of 500ms, which means that the outlet has entered the mode of excluding from the
    network and it is waiting for the gateway to complete the configuration.

    Keep pressing the button of the outlet, and then power up the outlet. The outlet will enter the factory test mode,
    in which all the operations of the outlet will not work and the green LED light will keep flashing.
    Exit from factory test mode: Power off, and then power the outlet on by un-pressing the button. And then it
    will enter the normal working mode.

    Factory reset Outlet

    a) Ensure that the outlet is powered up correctly.
    b) Press the button and maintain this action for 10 seconds, then release it after the green and red LEDs both
    light on. Then the outlet will restore all data to the factory defaults.
    Note: This mode can also delete the network information of the outlet and make the device exclude from the Z-Wave network that it has joined.
    Please use this procedure only when the network primary controller is missing or otherwise inoperable.

    Please note that this is a user manual Outlet from WINKA SYSIT is provided as is and without warranty; all information contained herein is provided by the manufacturer or the certifying body. The information provided is for reference only and is not intended to be used as a substitute for professional advice. ZWaveProducts.com only warrants and is only able to support products purchased directly from us. If you have Outlet and have not purchased it from us, please contact the manufacturer directly with any further questions you may have.