Siren (WK-0004) manual for Z-Wave

The following is an overview of the user manual for the Z-Wave product Siren (WK-0004)from WINKA SYSIT. To view other Z-Wave products and manuals from Winka Sysit follow that link.

  1. Overview
  2. Security
  3. Features
  4. Installation instructions

Overview

Name
Siren
SKU Code
WK-0004
Description
The Siren can be triggered to sound an alarm and flash its super-bright LEDs when some event occurs. To ensure you never miss important alerts from your smart home system and keep your smart home safe. It can plugs into your wall outlet directly, and there be 5 different alert tones for a range of specific events.
Version #
HW: 16 FW: 1.50 was the version certified
Certification #
ZC10-17105814
Certified
2017-10-24T04:32:41.321615
Z-Wave Version
6.51.09

Security

As a Z-Wave Plus certified product, Siren supports Z-Wave S2 security. The following security modes are directly supported:

    Features

    Winka Sysit describes Siren as having the following features:

    • Supported Notification Types
    • FLiRS capable
    • Supports Network Wide Inclusion
    • Supports Z-Wave Explorer Frames
    • Supports Z-Wave SmartStart allowing you to setup the product simply by scanning its QR code via

    Installation instructions

    a) Ensure that the siren is powered up correctly.
    b) Set Z-Wave Gateway entered inclusion mode.
    c) Press the button on the siren for three times quickly within 1.5 seconds. Then the LED light will flash for 5
    times with an interval of 500ms, which means that the siren has entered the inclusion mode and it is
    waiting for the host to complete the configuration.

    Keep pressing the button, and then power up the siren. The alarm will enter the factory test mode, in which all
    the operations in this manual will be invalid to the siren and LED will keep flashing.
    This operation will be valid only when no backup batteries are installed or the backup batteries have no power.
    Exit from factory testing mode: Power off, and then power the siren on by un-pressing the button. And then it
    will enter the normal working mode.

    a) Ensure that the siren is powered up correctly.
    b) Set Z-Wave Gateway entered exclusion mode.
    c) Press the button on the siren for three times quickly within 1.5 seconds. Then the LED light will flash for 5
    times with an interval of 500ms, which means that the alarm has entered the exclusion mode and it is
    waiting for the host to complete the configuration.

    Factory reset Siren

    a) Ensure that the siren is powered up correctly.
    b) Press the button and maintain this action for ten seconds, then release it after the LED light is on. Then the siren will erase all data and restore to the defaults.
    Note: This mode can also erase the network information of the siren and make the device exit from the Z-Wave. Please use this procedure only when the network primary controller is missing or otherwise inoperable.
    network that it has included.

    Please note that this is a user manual Siren from WINKA SYSIT is provided as is and without warranty; all information contained herein is provided by the manufacturer or the certifying body. The information provided is for reference only and is not intended to be used as a substitute for professional advice. ZWaveProducts.com only warrants and is only able to support products purchased directly from us. If you have Siren and have not purchased it from us, please contact the manufacturer directly with any further questions you may have.