nexTouch Push Button Lever Lock (NTB632-ZW2) manual for Z-Wave

The following is an overview of the user manual for the Z-Wave product nexTouch Push Button Lever Lock (NTB632-ZW2)from Yale. To view other Z-Wave products and manuals from Yale follow that link.

  1. Overview
  2. Security
  3. Features
  4. Installation instructions

Overview

Name
nexTouch Push Button Lever Lock
SKU Code
NTB632-ZW2
Description
Unlock what’s next in security with nexTouch™ commercial keypad door locks from Yale®. The nexTouch keyless electronic door lock combines a modern look with durability that is perfect for your multi-family property, small business office space, retail space, hotel, airport, restroom, or mixed-use commercial building. All nexTouch Locks are easy to use and install, and allow you to manage access with up to 500 unique PIN codes. The nexTouch is ANSI/BHMA Grade 1 Certified and weather resistant.
Version #
HW: 255 FW: 1.78:32.33 was the version certified
Certification #
ZC10-22067111
Certified
2022-06-15T14:04:46.50833
Z-Wave Version
6.51.07

Security

As a Z-Wave Plus certified product, nexTouch Push Button Lever Lock supports Z-Wave S2 security. The following security modes are directly supported:

    Features

    Yale describes nexTouch Push Button Lever Lock as having the following features:

    • Door Lock Type
    • Outdoor Use
    • Battery powered using batteries
    • Color
    • Firmware updatable via a compatible Z-Wave gateway
    • IP (Ingress Protection) Rated
    • Battery Quantity
    • FLiRS capable
    • Supports Network Wide Inclusion
    • Supports Z-Wave Explorer Frames
    • Supports Z-Wave SmartStart allowing you to setup the product simply by scanning its QR code via

    Installation instructions

    1. Enter the 4-8 digit master PIN code followed by the gear key.
    2. Press the 7 key followed by the gear key.
    3. Press the 1 key followed by the gear key.

    1. Enter the 4-8 digit master PIN code followed by the gear key.
    2. Press the 7 key followed by the gear key.
    3. Press the 3 key followed by the gear key.

    Press any key to wake up product

    Factory reset nexTouch Push Button Lever Lock

    Please use this procedure only when the network primary controller is missing or otherwise inoperable.
    1. Remove the inside lever with the lever removal tool.
    2. Remove battery cover using hex wrench provided with lock.
    3. Remove four (4) AA batteries.
    4. Remove the 10-32 x 3/4"" pan head screw from the center of the battery housing into the barrel nut of the outside assembly.
    5. Remove inside escutcheon. Cables may stay connected.
    6. Reinstall batteries
    7. On the back of the PC board, push and hold the Reset Button with the lever removal tool for 3 seconds.
    8. While continuing the press the reset button, temporarily remove one AA battery.
    9. Reinstall the battery
    10. Release reset button and wait 15 seconds. Speaker will announce ""Welcome to Yale""
    11. Reassemble escutcheon

    Please note that this is a user manual nexTouch Push Button Lever Lock from Yale is provided as is and without warranty; all information contained herein is provided by the manufacturer or the certifying body. The information provided is for reference only and is not intended to be used as a substitute for professional advice. ZWaveProducts.com only warrants and is only able to support products purchased directly from us. If you have nexTouch Push Button Lever Lock and have not purchased it from us, please contact the manufacturer directly with any further questions you may have.