Thermostatic Radiator Valve (Z-TRV-V01) manual for Z-Wave

The following is an overview of the user manual for the Z-Wave product Thermostatic Radiator Valve (Z-TRV-V01)from ZVIDAR. To view other Z-Wave products and manuals from ZVIDAR follow that link.

  1. Overview
  2. Security
  3. Features
  4. Installation instructions

Overview

Name
Thermostatic Radiator Valve
SKU Code
Z-TRV-V01
Description
Thermostatic Radiator Valves (TRVs) sense the air temperature around them and regulate the flow of water through the radiator which they are fitted to.
Version #
HW: 01 FW: 01.08 was the version certified
Certification #
ZC14-22100141
Certified
2022-10-10T12:49:29
Z-Wave Version
7.16.3

Security

As a Z-Wave Plus certified product, Thermostatic Radiator Valve supports Z-Wave S2 security. The following security modes are directly supported:

  • S2 Authenticated
  • S2 Unauthenticated

Features

ZVIDAR describes Thermostatic Radiator Valve as having the following features:

  • FLiRS capable
  • Supports Network Wide Inclusion
  • Supports Z-Wave Explorer Frames
  • Supports Z-Wave SmartStart allowing you to setup the product simply by scanning its QR code via

Installation instructions

SmartStart location

SmartStart QR code's location as follows: Refer to page 7 in English End User Manuals

Include the TRV into the Z-Wave network manually:
a. Power on your TRV,
b. Set your Z-Wave controller into add/inclusion mode.
c. In “OF” state, short press rotary plate three times until the screen shows “- -”.
d. The screen will show “PA” after few seconds, which meant the inclusion is successful. And
the signal icon will light on. Otherwise, the inclusion is failed, which you will need to repeat the process
form step b.

Exclude TRV from a Z-Wave network:
a. Power on your TRV
b. Set the Z-Wave primary controller into remove/exclusion mode.
c. In “OF” state, short press rotary plate three times until the screen shows “- -”.
d. The screen will turn back to “OF” after few seconds, which meant the inclusion is successful.
The signal icon light will be off. Otherwise, the exclusion is failed which you will need to repeat the
process form step b.

Factory reset Thermostatic Radiator Valve

4.3 Reset TRV to factory default
In “ OF” state, press and hold rotary plate for at least 5 seconds and release when the
8
screen will blink “OF”. When the reset is successful, the screen will show “OF” in solid for 2 seconds then turn off. And TRV will reset itself to factory default by sending a “Device Reset Locally Notification” to gateway.
Note: Please use this procedure only when the network primary controller is missing or otherwise inoperable.

Please note that this is a user manual Thermostatic Radiator Valve from ZVIDAR is provided as is and without warranty; all information contained herein is provided by the manufacturer or the certifying body. The information provided is for reference only and is not intended to be used as a substitute for professional advice. ZWaveProducts.com only warrants and is only able to support products purchased directly from us. If you have Thermostatic Radiator Valve and have not purchased it from us, please contact the manufacturer directly with any further questions you may have.