Dry Contact Sensor Gen5 (ZW097-A) manual for Z-Wave

The following is an overview of the user manual for the Z-Wave product Dry Contact Sensor Gen5 (ZW097-A)from Aeotec. To view other Z-Wave products and manuals from Aeotec follow that link.

  1. Overview
  2. Security
  3. Features
  4. Installation instructions

Overview

Name
Dry Contact Sensor Gen5
SKU Code
ZW097-A
Description
Aeon Labs Dry Contact Sensor Gen5 is a dry conatct sensor that can detect a variety of dry contact signals, you just need to connect the matched external sensor on it, such as the water level sensor, dry contact switch, dry contact relay and so on. In other words, it can be used if the external sensor is a dry contact.
It’s a security Z-Wave device that supports security encryption. Also it supports the “Over the Air Firmware Updating” that allows you wirelessly update its firmware if needs.
It can be included and operated in any Z-Wave network with other Z-Wave certified devices from manufacturers and/or other applications.
Version #
HW: 61 FW: 1.05 was the version certified
Certification #
ZC10-15090010
Certified
2015-09-08T10:36:47.501598
Z-Wave Version
6.51.06

Security

As a Z-Wave Plus certified product, Dry Contact Sensor Gen5 supports Z-Wave S2 security. The following security modes are directly supported:

    Features

    Aeotec describes Dry Contact Sensor Gen5 as having the following features:

    • FLiRS capable
    • Supports Network Wide Inclusion
    • Supports Z-Wave Explorer Frames
    • Supports Z-Wave SmartStart allowing you to setup the product simply by scanning its QR code via

    Installation instructions

    Turn the primary controller of Z-Wave network into inclusion mode, short press the product’s Action Button that you can find in the back of the product.

    Turn the primary controller of Z-Wave network into exclusion mode, short press the product’s Action Button that you can find in back of the product.

    Factory reset Dry Contact Sensor Gen5

    Press the Action Button once that you can find in back of the product for 20 seconds and then release. This procedure should only be used when the primary controller is inoperable.

    Press the Action Button once, which will trigger sending out the Wake up notification command, press and hold the Action Button for 3 seconds, which will toggle on/off the Sensor be waked up for 10 minutes.

    Support ""Over the Air Firmware Updating"" and “Z-Wave Security”.

    Please note that this is a user manual Dry Contact Sensor Gen5 from Aeotec is provided as is and without warranty; all information contained herein is provided by the manufacturer or the certifying body. The information provided is for reference only and is not intended to be used as a substitute for professional advice. ZWaveProducts.com only warrants and is only able to support products purchased directly from us. If you have Dry Contact Sensor Gen5 and have not purchased it from us, please contact the manufacturer directly with any further questions you may have.