TriSensor (ZWA005-B) manual for Z-Wave

The following is an overview of the user manual for the Z-Wave product TriSensor (ZWA005-B)from Aeotec. To view other Z-Wave products and manuals from Aeotec follow that link.

  1. Overview
  2. Security
  3. Features
  4. Installation instructions

Overview

Name
TriSensor
SKU Code
ZWA005-B
Description
Aeotec TriSensor is a universal Z-Wave Plus compatible product, consists of temperature, lighting and motion sensors, powered by a CR123A battery. It can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers and/or other applications. By the built-in motion sensor, an alam will be sent to the gateway when the motion sensor is triggered.
Version #
HW: 17 FW: 2.07:01.32 was the version certified
Certification #
ZC10-18056127
Certified
2018-05-01T05:46:57.203914
Z-Wave Version
6.71.01

Security

As a Z-Wave Plus certified product, TriSensor supports Z-Wave S2 security. The following security modes are directly supported:

  • S2 Authenticated
  • S2 Unauthenticated

Features

Aeotec describes TriSensor as having the following features:

  • Battery powered using CR123A batteries
  • Color
  • Sensors
  • Supported Notification Types
  • Battery Quantity
  • FLiRS capable
  • Supports Network Wide Inclusion
  • Supports Z-Wave Explorer Frames
  • Supports Z-Wave SmartStart allowing you to setup the product simply by scanning its QR code via

Installation instructions

Press once TriSensor’s Action Button. If it is the first installation, the yellow LED will keep solid until whole network processing is complete. If successful, the LED will flash white -> green -> white -> green, after 2 seconds finished. If failed, the yellow LED lasts for 30 seconds, then the green LED flashes once.
If it is the S2 encryption network, please enter the first 5 digits of DSK.

Press once TriSensor’s Action Button, the Purple LED will keep solid until whole network processing is complete. If the exclusion is successful, the LED will flash white -> green -
>white -> green and then LED will pulse a blue. If failed, the yellow LED lasts for 30 seconds, then the green LED flashes once.

Press and hold the button at least 2s until Red Led is on and then release the button,device will send wakeup notification to controller if device is in a Z-Wave network.

Factory reset TriSensor

1. Power up the device.
2. Press and hold the button for 15s until Red Led is blinking,then release the button. Note: Please use this procedure only when the network primary controller is missing or otherwise inoperable.

Please note that this is a user manual TriSensor from Aeotec is provided as is and without warranty; all information contained herein is provided by the manufacturer or the certifying body. The information provided is for reference only and is not intended to be used as a substitute for professional advice. ZWaveProducts.com only warrants and is only able to support products purchased directly from us. If you have TriSensor and have not purchased it from us, please contact the manufacturer directly with any further questions you may have.