Environmental Sensor (SES 303) manual for Z-Wave

The following is an overview of the user manual for the Z-Wave product Environmental Sensor (SES 303)from Secure Controls (UK). To view other Z-Wave products and manuals from Secure Controls follow that link.

  1. Overview
  2. Security
  3. Features
  4. Installation instructions

Overview

Name
Environmental Sensor
SKU Code
SES 303
Description
The Environmental Sensor (SES 303) measures temperature and humidity. The sensors are battery-operated devices which transmit information to an associated device in a network. It can support either 1 thermistor (SES 001) or up to 4 external digital temperature sensors (SES 002/003). SES 303 operates on 2x AA batteries, providing a nominal life of 2 years (with on-board sensors operating with the default configuration).
Version #
FW: 1.1 was the version certified
Certification #
ZC10-15010003
Certified
2015-01-22T08:03:35.3332
Z-Wave Version
6.51.02

Security

As a Z-Wave Plus certified product, Environmental Sensor supports Z-Wave S2 security. The following security modes are directly supported:

    Features

    Secure Controls describes Environmental Sensor as having the following features:

    • FLiRS capable
    • Supports Network Wide Inclusion
    • Supports Z-Wave Explorer Frames
    • Supports Z-Wave SmartStart allowing you to setup the product simply by scanning its QR code via

    Installation instructions

    Step 1.On the Z-Wave controller, select exclusion for removing a device from the network.
    Step 2: On the SES 303, press the button, hold and release after 1 second to send a request (Network Information Frame) to remove from the network. On successful exclusion the LED will flash 2 times. The total process can take up to 2 seconds. If the LED flashes 4-times this means that the exclusion process has failed, so try moving the SES 303 to another position and repeat the exclusion steps. The controller will show when the exclusion operation is successful.

    Factory reset Environmental Sensor

    Please use this procedure only when the primary controller is missing or otherwise inoperable.
    To reset the device to factory resst, press the button 3 times within 3 seconds it will put the device in factory default, that include setting all the configuration, Association to factory default and removing the device from Z-Wave network.

    Not applicable

    Device can be wakeup by button press of more then one second, devcie will stay in wakeup state for about 10 seconds.
    device will also wakeup on the every wakeup interval configured by controller. The minimum wakeup interval can be configured is 2 minutes and maximum wakeup interval can be configured is 24 hours in setps of one minte.
    Default wakeup interval is 24 hours.

    None

    Step 1.On the Z-Wave controller, select Include for adding a device to the network.
    Step 2: On the SES 303, press the button, hold and release after 1 second to send a request (Network Information Frame) to join the network. On successful inclusion the LED will flash 2 times. The total process can take up to 20 seconds. If the LED flashes 4-times this means that the inclusion process has failed, so try moving the SES 303 to another position and repeat the Inclusion steps. If the inclusion process fails again, the device may be already included in another network. So first exclude and then include the device. The controller will show when the inclusion operation is successful.

    Please note that this is a user manual Environmental Sensor from Secure Controls (UK) is provided as is and without warranty; all information contained herein is provided by the manufacturer or the certifying body. The information provided is for reference only and is not intended to be used as a substitute for professional advice. ZWaveProducts.com only warrants and is only able to support products purchased directly from us. If you have Environmental Sensor and have not purchased it from us, please contact the manufacturer directly with any further questions you may have.