SSR 302 (Dual Channel On/Off Power switch) (MAX10Z-382) manual for Z-Wave

The following is an overview of the user manual for the Z-Wave product SSR 302 (Dual Channel On/Off Power switch) (MAX10Z-382)from Secure Controls (UK). To view other Z-Wave products and manuals from Secure Controls follow that link.

  1. Overview
  2. Security
  3. Features
  4. Installation instructions

Overview

Name
SSR 302 (Dual Channel On/Off Power switch)
SKU Code
MAX10Z-382
Description
The SSR 302 is a 2-channel relay/switch, it forms part of central heating and hot water control system, it can be operated by any third party controllers/Thermostat using ‘Binary Switch CC’ commands.

SSR 302 will act as a repeater once added into the Z-Wave network, providing an alternative communication route for units which otherwise would not be within communication distance of each other.

SSR 302 has a fail-safe mode where by the relay is turned OFF if another 'Thermostat Mode SET' command has not been received within 60 minutes.
Version #
HW: 1 FW: 2.1 was the version certified
Certification #
ZC10-16075133
Certified
2016-07-05T20:34:08.1384
Z-Wave Version
6.51.06

Security

As a Z-Wave Plus certified product, SSR 302 (Dual Channel On/Off Power switch) supports Z-Wave S2 security. The following security modes are directly supported:

    Features

    Secure Controls describes SSR 302 (Dual Channel On/Off Power switch) as having the following features:

    • Color
    • Neutral Wire Required
    • Electric Load Type
    • IP (Ingress Protection) Rated
    • Switch Load Capacity Current
    • Loads Controlled
    • FLiRS capable
    • Supports Network Wide Inclusion
    • Supports Z-Wave Explorer Frames
    • Supports Z-Wave SmartStart allowing you to setup the product simply by scanning its QR code via

    Installation instructions

    Factory reset SSR 302 (Dual Channel On/Off Power switch)

    ""Please use this procedure only when the primary controller is missing or otherwise inoperable.""

    Follow ‘Exclusion’ steps.

    SSR 302 has a fail-safe mode where by the relay is turned OFF if another 'Thermostat Mode SET' command has not been received within 60 minutes.

    STEP 1: Ensure the LED is flashing RED on the SSR 302, if not follow the ‘Exclusion’ steps first.
    STEP 2: Put the 3rd party controller into inclusion mode.
    STEP 3: Press and hold both white buttons on the SSR 302 until the LED starts flashing green.
    The SSR 302 has been added onto the network and the LED will go solid amber.

    NOTE: If the LED does not go solid amber then the add process has been unsuccessful.

    STEP 1: Put the 3rd party controller into exclusion mode.
    STEP 2: Press and hold the two white buttons on the SSR 302.
    The SSR 302 has been removed from the network when the LED starts flashing red.

    NOTE: If the LED does not flash red then the remove process has been unsuccessful.

    Please note that this is a user manual SSR 302 (Dual Channel On/Off Power switch) from Secure Controls (UK) is provided as is and without warranty; all information contained herein is provided by the manufacturer or the certifying body. The information provided is for reference only and is not intended to be used as a substitute for professional advice. ZWaveProducts.com only warrants and is only able to support products purchased directly from us. If you have SSR 302 (Dual Channel On/Off Power switch) and have not purchased it from us, please contact the manufacturer directly with any further questions you may have.