Q Sensor (ZSE11) manual for Z-Wave

The following is an overview of the user manual for the Z-Wave product Q Sensor (ZSE11)from Zooz. To view other Z-Wave products and manuals from Zooz follow that link.

  1. Overview
  2. Security
  3. Features
  4. Installation instructions

Overview

Name
Q Sensor
SKU Code
ZSE11
Description
PRODUCT FEATURES:
- Quick and reliable motion alerts to Z-Wave hub
- Accurate temperature and humidity monitoring
- Lux sensor for smart light automations
- Battery or Micro USB power
- The latest S2 security and Z-Wave Plus chip
- Supports OTA firmware updates
- Built-in tamper switch for extra security

SPECIFICATIONS:
- Model Number: ZSE11
- Z-Wave Signal Frequency: 908.42 MHz
- Power: 2 x CR123A (3 V) batteries / Micro USB
- Motion Detection: up to 20 feet
- Humidity Detection Range: 0 – 100 %
- Light Sensor Detection Range: 0 – 65535 lux
- Operating Temperature: 32° – 104° F
- Dimensions: 2.3” x 2.3” x 2.2”
- Range: Up to 130 feet line of sight
- Installation and Use: Indoor only
Version #
HW: 1 FW: 1.04 was the version certified
Certification #
ZC10-21047020
Certified
2021-04-23T15:58:01.757274
Z-Wave Version
6.51.09

Security

As a Z-Wave Plus certified product, Q Sensor supports Z-Wave S2 security. The following security modes are directly supported:

    Features

    Zooz describes Q Sensor as having the following features:

    • Battery Quantity
    • FLiRS capable
    • Supports Network Wide Inclusion
    • Supports Z-Wave Explorer Frames
    • Supports Z-Wave SmartStart allowing you to setup the product simply by scanning its QR code via

    Installation instructions

    Put your Z-Wave hub into inclusion mode and click the Z-Wave button 3 times as quickly as possible. The LED
    indicator will start blinking to confirm inclusion mode and turn off once inclusion is completed. The sensor
    will automatically pair as a repeater if connected to USB power, no special button sequence required.

    1. Bring the sensor within direct range of your Z-Wave gateway (hub).
    2. Put the Z-Wave hub into exclusion mode (not sure how to do that? ask@getzooz.com).
    3. Press and release the Z-Wave button 3 times quickly.
    4. Your hub will confirm exclusion and the sensor will disappear from your controller's device list.

    The sensor’s wake-up interval is set to 4 hours by default to save battery life. Use the Wake Up Command Class to adjust the interval (in seconds, working in 3600s intervals, with 120 as min and 86400 as max values). Press and hold the ZWave button for 3 seconds to wake the sensor up manually. During wake-up, the sensor turns the Z-Wave radio for a couple of seconds to receive communication from the hub. Long wake-up interval will not affect how often the sensor reports motion or other values to your hub.

    Factory reset Q Sensor

    When your network’s primary controller is missing or otherwise inoperable, you may need to reset the device
    to factory settings manually. In order to complete the process, make sure the sensor is powered, then press
    and hold the Z-Wave button for at least 20 seconds.
    The LED indicator will start flashing and turn solid on for a couple of seconds to indicate successful reset.
    NOTE: All previously recorded activity and custom settings will be erased from the device’s memory.

    Please note that this is a user manual Q Sensor from Zooz is provided as is and without warranty; all information contained herein is provided by the manufacturer or the certifying body. The information provided is for reference only and is not intended to be used as a substitute for professional advice. ZWaveProducts.com only warrants and is only able to support products purchased directly from us. If you have Q Sensor and have not purchased it from us, please contact the manufacturer directly with any further questions you may have.